Illustration 1 | g01447939 |
![]() | |
Illustration 2 | g01447943 |
View A-A |
Direction of rotation for the electric motor from the pinion end ... Clockwise
No load conditions at
- Speed ... 6900 ± 1800 rpm
- Current draw ... 150.5 ± 27.5 Amp
- Voltage ... 11 V
- Current draw ... 150.5 ± 27.5 Amp
(B) Clearance between the pinion and the housing ...
(1) Final installation torque for the ground terminal nut ...
Note: A maximum of three cable terminals or wire terminals may be used with the battery terminal nut (2). A maximum of two of the cable terminals may be equal to or greater than 0 AWG.
(2) Final installation torque for the battery terminal nut ...
(3) Final installation torque for the start relay terminal screw ...
(4) Final installation torque for the ground terminal nut ...
Note: The switch terminal must be insulated with heat shrink tubing. Do not use molded terminals.
(5) Final installation torque for the switch terminal nut ...
(6) Final installation torque for the motor terminal nut ...
(7) Final installation torque for the motor frame terminal nut ...
Solenoid assembly
Current consumption at 10 V and
- Pull-in windings ... 97 Amp
- Hold-in windings ... 18 Amp