ES12F, UPS 1000S and UPS 1200S Uninterruptible Power Supplys Specifications Caterpillar


Specifications
`
1.1. UPS 1200
2.2. Technical Data
3.2. Specifications
4.2. Dimensions and Weights
5.2. Environmental
6.2. Safety
7.2. Ride Through Times
8.1. UPS 1000
9.2. Technical Data
10.2. Specifications
11.2. Dimensions and Weights
12.2. Environmental
13.2. Safety
14.2. Ride Through Times

UPS 1200

Technical Data

Table 1
Maximum kVA     1200    
Maximum ekW     960    
Input voltage     480    
Output voltage     480    
AC input current (Nominal Amps)     1205    
Maximum amps incl. recharge     1600    
AC output current nominal amps     1445    
System efficiency     97 percent    

Specifications

Table 2
INPUT    
Voltage     480 VAC 3 phase, 3-wire plus ground (from grounded wye source)    
Voltage Range     +10 percent/-15 percent (programmable)    
Frequency     60Hz    
Power Factor     0.99 at rated load and nominal voltage    
Harmonic Current Distortion    
Linear load     less than 3 percent at 100 percent resistive load    
Non-linear load     less than 8 percent with 100 percent non-linear load    
Surge Withstand     Meets IEEE 587/ANSI C62.41    
Walk-in     1 to 15 seconds (programmable)    
Bypass Source     Same as input source – Synchronized frequency, phase and voltage    
Bypass Voltage Window     ± 10/15 percent (programmable within range)    
OUTPUT    
Voltage     480 VAC, 3 phase, 3-wire plus ground (4-wire optional)    
Voltage Regulation    
Steady-state     ±1 percent of nominal for ± 10 percent input and balanced or unbalanced load 0.8 lag to .9 lead pf; 7 percent at –15 percent input voltage    
Transient     ±5 percent of nominal for 100 percent load step; or loss/ return of input    
Recovery Time     50 millisecond maximum    
Bypass Trigger     Programmable up to ±10 percent    
Frequency Regulation    
Normal Operation     Synchronized to input    
Free Running     0.1 percent stability    

Table 3
Synch Window     Adjustable over a range of at least 0.3 Hz to 3 Hz    
Frequency Slew Rate     Adjustable over a range of at least 0.2 Hz/second to 5 Hz/second    
Load Power Factor     0.8 lag to 0.9 lead for specified regulation and rating. 0.4 lag to 0.7 lead with reduced regulation or load.    
Voltage Unbalance and Distortion    
Balanced Load     less than 1 percent voltage unbalance and less than 1 phase displacement    
50 percent Unbalanced Load     less than 3 percent voltage unbalance and less than 3 percent phase displacement    
Linear Load     less than 3 percent THD less than 2 percent SHD    
100 percent Non Linear Load (in accordance with EN 50091-3)     less than 5 percent THD    
Load Imbalance     The UPS is capable of supporting any combination of unbalanced load that does not exceed the maximum phase currents and the total output limitations of the UPS.    
Overload Capability (nominal line without bypass)    
Continuous     105 percent    
1 Minute     125 percent    
5 Seconds     Up to 150 percent    

Dimensions and Weights

Table 4
All Cabinets    
Depth     1016 mm (40 inch)    
Cabinet height (without DC bus)    
1981 mm (78 inch)    
System height (with DC bus)    
2319 mm (91.3 inch)    
Individual Cabinets    
4-wire (option)    
Width    
1981 mm (78 inch)    
Weight    
3448 kg (7600 lb)    
Maintenance Bypass (option)    
Width    
533 mm (21.0 inch)    
Weight    
1134 kg (2500 lb)    
Bottom Entry (option)    
Width    
1067 mm (42.0 inch)    
Weight    
272 kg (600 lb)    
Input/Output    
Width    
1067 mm (42.0 inch)    
Weight    
1134 kg (2500 lb)    
Static Switch    
Width    
1067 mm (42.0 inch)    
Weight    
907 kg (2000 lb)    
Control (1)    
Width    
914 mm (36.0 inch)    
Weight    
907 kg (2000 lb)    
Inverter (2)    
Width    
1067 mm (42.0 inch)    
Weight    
771 kg (1700 lb)    
Energy Storage (3)    
Width    
1067 mm (42.0 inch)    
Weight    
3040 kg (6700 lb)    
( 1 ) Ships attached to Inverter Cabinet.
( 2 ) Ships attached to Control Cabinet.
( 3 ) 2 per Standard System

Environmental

Table 5
Acoustical noise     less than 77dBA at 1.52 m (5 ft)    
Temperature        
Operating    
0 °C (32 °F) to
40 °C (104 °F)    
Storage    
−25 °C (−13 °F) to
70 °C (158 °F)    
Humidity     5 percent to 95 percent (non-condensing)    
Altitude     Up to 914.4 m (3,000 ft) (de-rate operating temperature range for higher elevation)    
Emissions and Immunity     FCC Class A, Subpart J of Part 15/ EN 50091-2    

Safety

Table 6
UL 1778 Listed    
CUL CAN/CSA 22.2 No. 107.1 Listed    

Ride Through Times

Table 7
Number of Energy Storage Cabinets     100 Percent load     75 Percent load     50 Percent load     25 Percent load    
2     13.5     17     26     50    
3     20     25     39     75    
4     27     34     52     100    

UPS 1000

Technical Data

Table 8
Maximum kVA     1000 rated at kW    
Maximum ekW     900    
Input voltage     380, 400, 415    
Output voltage     380, 400, 415    
AC input current (Nominal Amps)     1475, 1400, 1350    
Maximum amps incl. recharge     1600    
AC output current nominal amps     1445, 1445, 1393    
System efficiency     94 percent    

Specifications

Table 9
INPUT    
Voltage     380, 400, 415 VAC 3 phase, 3-wire plus ground (from grounded wye source)    
Voltage Range     +10 percent/-15 percent (programmable)
+ 10% at 380 V    
Frequency     50Hz or 60 Hz    
Power Factor     0.99 at rated load and nominal voltage    
Harmonic Current Distortion    
Linear load     less than 3 percent at 100 percent resistive load    
Non-linear load     less than 8 percent with 100 percent non-linear load    
Surge Withstand     Meets IEEE 587/ANSI C62.41    
Walk-in     1 to 15 seconds (programmable)    
Bypass Source     Same as input source – Synchronized frequency, phase and voltage    
Bypass Voltage Window     ± 10/15 percent (programmable within range)
+10% at 380 V    
OUTPUT    
Voltage     Same as input, galvanically isolated 3-phase, 4-wire plus ground    
Voltage Regulation    
Steady-state     ±1 percent of nominal for ± 10 percent input and balanced or unbalanced load, 7 percent at –15 percent input voltage and rated load    
Transient     ±5 percent of nominal for 50 percent load step or loss return of input    
Recovery Time     50 millisecond maximum    
Bypass Trigger     Programmable up to ±10 percent    
Frequency Regulation    
Normal Operation     Synchronized to input    
Free Running     0.1 percent stability    

Table 10
Synch Window     Adjustable over a range of at least 0.3 Hz to 3 Hz    
Frequency Slew Rate     Adjustable over a range of at least 0.3 Hz/second to 3 Hz/second    
Load Power Factor     0.8 lag to 0.9 lead for specified regulation and rating. 0.4 lag to 0.7 lead with reduced regulation or load.    
Voltage Distortion    
Balanced Load     less than 1 percent voltage unbalance and less than 1 degree of phase displacement    
50 percent Unbalanced Load     less than 3 percent voltage unbalance and less than 3 degrees phase displacement    
Linear Load     less than 3 percent THD less than 2 percent SHD    
100 percent Non Linear Load (in accordance with EN 50091-3)     less than 5 percent THD    
Load Imbalance     The UPS is capable of supporting any combination of unbalanced load that does not exceed the maximum phase currents and the total output limitations of the UPS.    
Overload Capability (nominal line without bypass)    
Continuous     105 percent    
1 Minute     125 percent    
5 Seconds     Up to 150 percent    

Dimensions and Weights

Table 11
All Cabinets    
Depth    
1016 mm (40 inch)    
Cabinet height (without DC bus)    
1981 mm (78 inch)    
System height (with DC bus)    
2319 mm (91.3 inch)    
Individual Cabinets    
4-wire (option)    
Width    
1981 mm (78 inch)    
Weight    
3448 kg (7600 lb)    
Maintenance Bypass (option)    
Width    
533 mm (21.0 inch)    
Weight    
1134 kg (2500 lb)    
Bottom Entry (option)    
Width    
1067 mm (42.0 inch)    
Weight    
272 kg (600 lb)    
Input/Output    
Width    
1067 mm (42.0 inch)    
Weight    
1134 kg (2500 lb)    
Static Switch    
Width    
1067 mm (42.0 inch)    
Weight    
907 kg (2000 lb)    
Control (1)    
Width    
914 mm (36.0 inch)    
Weight    
907 kg (2000 lb)    
Inverter (2)    
Width    
1067 mm (42.0 inch)    
Weight    
771 kg (1700 lb)    
Energy (3)    
Width    
1067 mm (42.0 inch)    
Weight    
3040 kg (6700 lb)    
( 1 ) Ships attached to Inverter Cabinet.
( 2 ) Ships attached to Control Cabinet.
( 3 ) Each CSHV, 2 per System

Environmental

Table 12
Acoustical noise     less than 77dBA at 1.52 m (5 ft)    
Temperature        
Operating    
0 °C (32 °F) to
40 °C (104 °F)    
Storage    
−25 °C (−13 °F) to
70 °C (158 °F)    
Humidity     5 percent to 95 percent (non-condensing)    
Altitude     Up to 914.4 m (3,000 ft) (de-rate operating temperature range for higher elevation)    
Emissions and Immunity     FCC Class A, Subpart J of Part 15/ EN 50091-2    

Safety

Table 13
EN 50091-1-1    
CE Mark    

Ride Through Times

Table 14
Number of Energy Storage Cabinets     100 Percent load     75 Percent load     50 Percent load     25 Percent load    
2     14     19     28     56    
3     21     28     42     84    
4     28     37     56     112